Interdisciplinary Journal of Civil Engineering

Interdisciplinary Journal of Civil Engineering

Effect of Single Friction Pendulum Isolator on Reduction of Drift Ratio in Compliance with FEMA P695

Document Type : Original Article

Authors
Faculty of Civil, Water, and Environmental Engineering, Shahid Beheshti University, Tehran, Iran
10.48308/ijce.2026.107748
Abstract
This study investigates the effect of single friction pendulum (SFP) bearings on the maximum interstory drift of steel moment-resisting frames. Three two-dimensional models, representing 3-, 6-, and 9-story buildings, were examined in fixed-base and base-isolated configurations using OpenSeesPy. The bearings were selected through a simplified design procedure and modeled with nonlinear friction-pendulum elements, whereas the steel beams and columns were represented by elastic elements. Each configuration was subjected to the same 44 horizontal far-field earthquake components from the FEMA P695 suite. For every analysis, the largest absolute interstory drift ratio was extracted and compared with the corresponding fixed-base response. The mean record-wise reductions were 51.62%, 51.80%, and 55.59% for the 3-, 6-, and 9-story frames, respectively. All three isolated models also showed lower median peak drifts and smaller sample standard deviations. The paired record comparisons and distributions indicate a clear overall reduction in superstructure deformation, although the magnitude of that reduction varies with the earthquake component. These results demonstrate the potential of SFP bearings to improve drift control across the investigated steel frame configurations.
Keywords

Almazán, J. L., & De la Llera, J. C. (2002). Analytical model of structures with frictional pendulum isolators. Earthquake Engineering & Structural Dynamics, 31(2), 305–332.
Almazán, J. L., De la Llera, J. C., & Inaudi, J. A. (1998). Modelling aspects of structures isolated with the frictional pendulum system. Earthquake Engineering & Structural Dynamics, 27(8), 845–867.
Buckle, I. G., & Mayes, R. L. (1990). Seismic isolation: History, application, and performance—A world view. Earthquake Spectra, 6(2), 161–201.
Constantinou, M. C., Mokha, A., & Reinhorn, A. M. (1990). Teflon bearings in base isolation II: Modeling. Journal of Structural Engineering, 116(2), 455–474.
Deringöl, A. H., & Güneyisi, E. M. (2019). Effect of friction pendulum bearing properties on behaviour of buildings subjected to seismic loads. Soil Dynamics and Earthquake Engineering, 125, 105746.
Federal Emergency Management Agency. (2009). Quantification of building seismic performance factors (FEMA P695). Federal Emergency Management Agency.
Fenz, D. M., & Constantinou, M. C. (2006). Behaviour of the double concave Friction Pendulum bearing. Earthquake Engineering & Structural Dynamics, 35(11), 1403–1424.
Jangid, R. S. (2005). Optimum friction pendulum system for near-fault motions. Engineering Structures, 27(3), 349–359.
Jangid, R. S., & Datta, T. K. (1995). Seismic behavior of base-isolated buildings: A state-of-the-art review. Proceedings of the Institution of Civil Engineers – Structures and Buildings, 110(2), 186–203.
Kelly, J. M. (1999). The role of damping in seismic isolation. Earthquake Engineering & Structural Dynamics, 28(1), 3–20.
Kitayama, S., & Cilsalar, H. (2022). Seismic loss assessment of seismically isolated buildings designed by the procedures of ASCE/SEI 7-16. Bulletin of Earthquake Engineering, 20, 1143–1168.
Kitayama, S., & Constantinou, M. C. (2018). Collapse performance of seismically isolated buildings designed by the procedures of ASCE/SEI 7. Engineering Structures, 164, 243–258.
Matsagar, V. A., & Jangid, R. S. (2008). Base isolation for seismic retrofitting of structures. Practice Periodical on Structural Design and Construction, 13(4), 175–185.
McKenna, F. (2011). OpenSees: A framework for earthquake engineering simulation. Computing in Science & Engineering, 13(4), 58–66.
Mokha, A., Constantinou, M. C., & Reinhorn, A. M. (1990). Teflon bearings in base isolation I: Testing. Journal of Structural Engineering, 116(2), 438–454.
Mokha, A., Constantinou, M. C., Reinhorn, A. M., & Zayas, V. A. (1991). Experimental study of friction-pendulum isolation system. Journal of Structural Engineering, 117(4), 1201–1217.
Mosqueda, G., Whittaker, A. S., & Fenves, G. L. (2004). Characterization and modeling of friction pendulum bearings subjected to multiple components of excitation. Journal of Structural Engineering, 130(3), 433–442.
Naeim, F., & Kelly, J. M. (1999). Design of seismic isolated structures: From theory to practice. John Wiley & Sons.
Shome, N., Cornell, C. A., Bazzurro, P., & Carballo, J. E. (1998). Earthquakes, records, and nonlinear responses. Earthquake Spectra, 14(3), 469–500.
Warn, G. P., & Ryan, K. L. (2012). A review of seismic isolation for buildings: Historical development and research needs. Buildings, 2(3), 300–325.
Zayas, V. A., Low, S. S., & Mahin, S. A. (1990). A simple pendulum technique for achieving seismic isolation. Earthquake Spectra, 6(2), 317–333.
Zhu, M., McKenna, F., & Scott, M. H. (2018). OpenSeesPy: Python library for the OpenSees finite element framework. SoftwareX, 7, 6–11.